BTXBM - INTERSPEED CURING AGENT, BLA000
- MSDS: BTXBM
- Manufacturer: INTERNATIONAL PAINT INC
- Product Name: INTERSPEED CURING AGENT, BLA000
- National Stock Number: 8010-00N045228
Product Identification
Product ID:INTERSPEED CURING AGENT, BLA000
MSDS Date:11/20/1991
FSC:8010
NIIN:00N045228
MSDS Number: BTXBM
Responsible Party
UNION, NJ 08083-0386
US
Emergency Phone: 713-682-1711
Info Phone: 713-682-1711
Cage: 26351
Contractor
Telephone: 800-589-1267/800-854-6813
Cage: 26351
Ingredients
SOLVENT NAPHTHA (PETROLEUM), LIGHT AROMATIC; (AROMATIC
CAS: 64742-95-6
RTECS: WF3400000
Fraction By Weight: 50-55%
OSHA PEL 100 PPM (MFR)
ACGIH TLV: 100 PPM (MFR)
EPOXY RESIN
CAS: 25068-38-6
RTECS: KC2100000
Fraction By Weight: 1-5%
OSHA PEL N/K
ACGIH TLV: N/K
CARBON TETRACHLORIDE; (TRACE TETRCHLOROMETHANE, CCL4
CAS: 56-23-5
RTECS: FG4900000
Fraction By Weight: 0.458%
OSHA PEL 2 PPM
ACGIH TLV: 5 PPM, S
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
LIVER,
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYES:CAN CAUSE IRRIT W/RED, TEAR
& BLURRED VISION. SKIN: IRRITATING. MAY RESULT IN DERM. INHAL: MAY
CAUSE IRRIT. INGEST: MAY CAUSE GI IRRIT. CHRONIC: CHRONIC OVEREXP
TO, & MISUSE OF, SOLV HAS BE EN LINKED TO PERM BRAIN & NERV SYS
DAM.CHLOROCARBON MATLS HAVE PRODUCED SENSITIZATION OF MYOCARDIUM
TO(EFTS OF OVEREXP)
Explanation of Carcinogenicity:CARBON TETRACHLORIDE: IARC MONOGRAPHS,
SUPPLEMENT, VOL 7, PG 143, 1987: GRP 2B. NTP 6TH ANNUAL REPORT ON
CARCIN, (ING 4)
Effects of Overexposure:HLTH HAZ: EPINEPRHINE & COULD HAVE SIMILAR EFT
IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY
OR CHRONICALLY EXPOSED TO CHLOROCA RBONS .
Medical Cond Aggravated by Exposure:SKIN AND RESPIRATORY CONDITIONS.
First Aid
First Aid:EYES: FLUSH IMMED WITH COPIOUS QTY OF WATER FOR @ LST 15 MIN.
GET MED ATTN IMMED. SKIN: REMOVE CONTAMD CLTHG, WASH SKIN W/PLENTY
OF SOAP AND WATER. LAUNDER CLOTHES BEFORE REUSE. INHAL: REMOVE TO
FRESH AIR. GIVE ARTF RESP IF NEEDED. GET MEDATTN. INGEST: CALL A
PHYS IMMED TO DETERMINE WHETHER OR NOT TO INDUCE VOMITING.
Fire Fighting
Flash Point:100F,38C
Lower Limits:0.9%
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:NIOSH/MSHA APPRVD PRESS DEMAND SCBA & FULL
PROT EQUIP. SMOTHER FLAMES W/ONE OF ABOVE EXTING MEDIA. WATER MAY
BE USED TO COOL UNOPENED CONTRS, BUT (SUPDAT)
Unusual Fire/Explosion Hazard:NONE KNOWN UNLESS NOTED. CONTS FLAMM
SOLV. DO NOT USE IN AREAS WHERE SPARK/OPEN FLAME ARE PRESENT.
THERMAL DECOMP PROD MAY INCL HCL & PHOSGENE .
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. AVOID
INHALATION OF VAPORS. VENTILATE AREA. CLEAN UP WITH ABSORBENT
MATERIALS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN BLDG DESIGNED & PROTECTED FOR
STOR OF LIQ W/NFPA CLASS II COMBUSTIBLE. AVOID BRTHG DUST/CHIPS
FROM SAND/BLAST SURF COATED W/PROD.
Other Precautions:RECOMM GROUND & BOND OF CONTRS WHEN TRANSFERRING LIQ
& POWDERS TO AVOID STATIC CHARGE BUILDUP. NO SMOKING IN AREA OF
USE.DO NOT USE IN GEN VICIN OF ACR WELD, OPEN FLAMES/HOT SURF. HEAT
&/OR UV RADIA M AY CAUE FORM OF HCL &/OR PHOSGENE.
Exposure Controls
Respiratory Protection:IN OUTDOOR/OPEN AREAS, W/UNRESTRICTED VENT, USE
A NIOSH/MSHA APPRVD FILTER RESP TO REMOVE SOLID-AIR-BORNE PARTICLES
OF OVERSPRAY DURING SPRAY APPLICATN. IN RESTRICTED VENT AREAS, USE
A NIOSH/ MSHA APP RVD RESP I/A/W 29CFR 1910.134 (SUPDAT)
Ventilation:PROVIDE SUFFICIENT VENT, IN VOL & PATTERN TO KEEP TLV & PEL
OF HAZ INGRED BELOW LIMITS, & TO REMOVE DECOMP (SUPP DATA)
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORK GOGG (SUPP DATA)
Other Protective Equipment:WEAR APPROPRIATE IMPERVIOUS PROTECTIVE
CLOTHING TO PREVENT SKIN CONTACT.
Work Hygienic Practices:REMOVE AND WASH SOILED CLOTHING BEFORE REUSE,
WASH HANDS BEFORE EATING OR SMOKING.
Supplemental Safety and Health
FIRE FIGHT PROC: MUST NOT BE USED AS AN EXTING MEDIA. TAKE CARE TO PVNT
SPREAD OF BURNING LIQ W/WATER. CLSD CONTRS MAY EXPLODE WHEN EXPOSED
TO EXTREME HEAT. RESP PROT:TO REMOVE A COMBINATION OF PARTIC ULATES
& VAPS. VENT:PROD DURING WELD/FLAME CUTTING ON SURF COATED W/PROD.
EYE PROT: W/FULL LNGHT FSHLD .
Chemical Properties
HCC:F4
Boiling Pt:B.P. Text:344F,173C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:1.10
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:57
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS.
Stability Condition to Avoid:DIRECT HEAT, FLAME/SPARK.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
VARIOUS HYDROCARBON FRAGMENTS, ALDEHYDES, CCL4, HCL, PHOSGENE.
Disposal
Waste Disposal Methods:DISPOSE I/A/W LOCAL, STATE, AND FEDERAL
REGULATIONS. DO NOT INCINERATE UNOPENED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.